title: "NEXTuino PEAK CORE — Compact ATmega2560 Industrial PLC"
url: "https://maker.wiznet.io/scott/resellers/nextuino-peak-core--compact-atmega2560-industrial-plc/"
markdown_url: "https://maker.wiznet.io/scott/resellers/nextuino-peak-core--compact-atmega2560-industrial-plc/md"
type: "VAR: Value-Added Reseller Products"
author: "NEXTuino"
author_url: "https://www.nextuino.com/products/peak/core"
editor: "WIZnet"
editor_url: "https://maker.wiznet.io/"
original_author: "NEXTuino"
original_url: "https://www.nextuino.com/products/peak/core"
published: "2026-11-19"
language: "en"
hardware: ["WIZnet W5100"]
likes: 0
views: 31
comments: 0
source: "WIZnet Makers (https://maker.wiznet.io/)"
---

# NEXTuino PEAK CORE — Compact ATmega2560 Industrial PLC

> NEXTuino PEAK CORE: The New Name for CONTROLLINO MAXI, and How a W5100 Puts an 8 KB AVR on the Network

Original author: NEXTuino (source: https://www.nextuino.com/products/peak/core)

## Components

- **WIZnet W5100** x 1 ([docs](https://docs.wiznet.io/Product/Chip/Ethernet/W5100))

## Article

## Summary

**NEXTuino PEAK CORE** is a DIN-rail PLC built on the **ATmega2560**. The maker's family overview maps it to the former **CONTROLLINO MAXI Pure**. A 2026 product change notice (PCN) confirms that only the **name and part number changed** from the old **100.100.10**; the **circuit and firmware are unchanged**. Ethernet is handled by a **WIZnet W5100**. Because this chip **processes TCP/IP in hardware (TOE)**, an 8-bit MCU with only **8 KB of SRAM** can still act as a Modbus TCP server or an HTTP client.

→ Product page: <https://www.nextuino.com/products/peak/core>

## Overview

PEAK CORE is a compact PLC aimed at **OEM machine builders and panel builders**. It fits **12 digital inputs** (10 of them analog-capable), **12 transistor outputs**, **10 relay outputs**, **RS-485** and **Ethernet** into a 72 × 90 × 62 mm housing. You program it in the Arduino IDE with the usual `setup()`/`loop()`.

**CORE** in the name means **the variant without Arduino pin headers**. The maker states that "MCU and I/O mapping are identical," so PEAK firmware runs unchanged. Dropping the headers reduces board height and BOM cost. It suits production machines that will never take a shield.

The same hardware has already appeared on maker.wiznet.io several times under the name **CONTROLLINO MAXI**. This article covers what those posts left out: **how the name changed**, **what the W5100 does on an 8 KB MCU**, and **how to budget its four sockets**.

→ Earlier introduction: <https://maker.wiznet.io/irina/resellers/controllino-maxi/>
→ Sibling variant: <https://maker.wiznet.io/bruno/resellers/controllino-maxi-power-automation-1/>

## Why the Name Changed: From CONTROLLINO to NEXTuino

### Lineage

| When | What happened | Source |
| --- | --- | --- |
| Launch date unconfirmed | **Conelcom GmbH** of Innsbruck, Austria, releases the Arduino-compatible PLC **CONTROLLINO** (MINI, MAXI, MEGA) | Manufacturer line in CONTROLLINO manuals |
| **2024-10-31** | **Industrial Shields** (Boot & Work Corp) of Barcelona, Spain, takes over **exclusive production and marketing** of the CONTROLLINO brand. Founder Marco Riedesser keeps designing products | Industry report (automation.com); company name from the PCN header |
| Effective **2026-05-01** | Industrial Shields issues **PCN-IS-2026-001** (dated 2026-07-08), moving CONTROLLINO-compatible part numbers to **12-digit NEXTuino part numbers** | PCN document |

→ PCN document (RS document server): <https://docs.rs-online.com/1718/A700000015864598.pdf>
→ Partnership report: <https://www.automation.com/article/agreement-industrial-shields-controllino>

### What the PCN Says

The PCN's impact table lists **Form, Fit, Function, hardware revision, software/firmware, pricing and lead time as "No change,"** and states it is a part number update only. The mapping for the PEAK line and CREST CORE is below.

| Old MPN | NEXTuino name | New MPN |
| --- | --- | --- |
| 100.100.00 | NEXTuino **PEAK** | 042003000100 |
| **100.100.10** | NEXTuino **PEAK CORE** | **042003000200** |
| 100.101.00 | NEXTuino PEAK FLEX | 042003000300 |
| 100.101.10 | NEXTuino PEAK FLEX CORE | 042003000400 |
| 100.200.10 | NEXTuino CREST CORE | 042004000200 |

The PEAK CORE datasheet header also reads **042003000200 Rev.1.0**, matching the new PCN part number. The maker's Family Overview datasheet maps **PEAK CORE = CONTROLLINO MAXI Pure**.

→ Family overview: <https://www.nextuino.com/assets/datasheets/NEXTuino_Family_Overview_Datasheet.pdf>

**For readers, this means one thing.Code, pin macros and forum answers written for CONTROLLINO MAXI still apply to PEAK CORE.** Some distributors still list the old name, so match on the **part number** when you order.

### Standards

The datasheet lists **EN 61010-1 / EN 61010-2-201 / EN 61131-2**. EN 61131-2 covers functional and EMC requirements and tests for PLC equipment. EN 61010-2-201 covers electrical safety for control equipment. Certificate numbers are not published.

## Architecture

The pin numbers come from the MAXI definitions in the CONTROLLINO library's `Controllino.h`.

- **Ethernet**: `CONTROLLINO_ETHERNET_CHIP_SELECT 70`, `CONTROLLINO_ETHERNET_INTERRUPT 71`

- **RTC**: `CONTROLLINO_RTC_CHIP_SELECT 72`, `CONTROLLINO_RTC_INTERRUPT 73`

- **RS-485**: `CONTROLLINO_RS485_TX 14`, `CONTROLLINO_RS485_RX 15`, `CONTROLLINO_RS485_DE 75`, `CONTROLLINO_RS485_nRE 76`

→ Library: <https://github.com/CONTROLLINO-PLC/CONTROLLINO_Library>

**The W5100 and the RTC share one SPI bus.** Chip-select lines keep them apart, so firmware must handle the CS pins correctly. The Limitations section covers this.

## Technology Background

### Modbus RTU and Modbus TCP: Same Commands, Different Transport

- **Concept**: Modbus is an **application-layer protocol** that defines which registers to read and write. The command part (PDU: function code + data) is identical in RTU and TCP. **Only the transport differs**

- **RTU**: Over serial (RS-485), a frame is **slave address + PDU + CRC-16**. Silent intervals between characters mark frame boundaries

- **TCP**: Over a TCP connection on **port 502**, a frame is a **7-byte MBAP header + PDU**. TCP handles error detection and retransmission, so no CRC is added

- **Role in this product**: PEAK CORE is a compact PLC with **both RS-485 (RTU) and Ethernet (TCP)**. It can **bridge both sides**: poll field meters over RS-485 and expose the same registers to SCADA or HMI over Ethernet. The OpenPLC Editor firmware source has a branch that includes `Controllino.h` when `CONTROLLINO_MAXI` or `CONTROLLINO_MEGA` is defined

→ Modbus specifications: <https://www.modbus.org/modbus-specifications>
→ OpenPLC Editor source: <https://github.com/Autonomy-Logic/openplc-editor>

### EN 61131-2 and EN 61010-2-201: What PLC Standards Leave in a Datasheet

- **Concept**: IEC/EN 61131-2 defines **functional requirements (power, I/O characteristics and so on), EMC requirements and their verification tests** for PLC equipment. Since the 2017 edition, **safety requirements have moved to IEC 61010-2-201**

- **Core idea**: A typical microcontroller board talks about "3.3 V logic." PLC standards ask **where 0 ends and 1 begins at 12/24 V field voltage**, and how much ESD and surge the device survives

- **Role in this product**: The datasheet numbers answer the questions these two standards ask
  - 24 V range inputs: **0–7.2 V is Low, 18–26.4 V is High**, input current **below 3 mA**
  - ESD: **±4 kV contact / ±8 kV air**
  - Shock: **15 g, 11 ms half-sine**, all three axes
  - Vibration: **1.75 mm amplitude at 5–9 Hz**, **0.5 g at 9–150 Hz** (sine)
  - Pollution degree **PD2**, altitude up to **2000 m**

These numbers are **the difference between a PLC and "an Arduino board in a case."**

## Technical Highlights

- **CORE without headers**: Same I/O mapping as PEAK, minus the pin headers. Inside a machine that never takes a shield, **height and part count go down**

- **12 V / 24 V with LED indication**: Two power LEDs **turn green or orange** depending on the input range (10.2–15.0 V / 20.4–30.0 V). You can check the supply range on site at a glance

- **Isolated relays, non-isolated DI/DO**: Relays have **3000 V AC coil-to-contact isolation for 1 minute**. Digital inputs and transistor outputs are marked **"no galvanic insulation,"** so keep them on a common ground reference

- **PWM and relays**: Transistor outputs support **PWM at 5–95 % duty**. When relays are driven by PWM, the datasheet says they switch on above **30 % duty**

- **Built-in RTC**: An **RV-2123** RTC on SPI lets you run time-based schedules even without Ethernet

- **No RS-485 termination**: Add an external 120 Ω resistor if the PLC sits at the end of the bus (datasheet: "no termination inside")

## Where WIZnet Fits: Taking TCP off an 8 KB SRAM

### TOE Verdict: Yes

PEAK CORE's Ethernet runs on the **W5100's hardware TCP/IP (TOE)**. The evidence:

- The product page's communication section explicitly lists **"Ethernet (W5100)"**

- Since CONTROLLINO BSP 3.0.0, the board uses the **standard Arduino `Ethernet` library** (library README, FAQ 9). That library has no software stack such as lwIP. It **drives the WIZnet chip's hardware sockets directly through registers**

- The library's `socket.cpp` contains `if (chip == 51) maxindex = 4;`. On a W5100 (chip ID 51), it uses **at most four hardware socketsW5100 key specs** (per WIZnet's official documentation)

| Item | Value |
| --- | --- |
| Hardware sockets | **4** simultaneous |
| Internal buffer | **16 KB** (8 KB TX + 8 KB RX, each split across sockets) |
| Protocols in hardware | TCP, UDP, ICMP, IGMPv1/v2, IPv4, ARP, PPPoE |
| PHY | Integrated 10BASE-T / 100BASE-TX, auto-negotiation |
| Host interface | SPI or parallel bus |

→ W5100 documentation: <https://docs.wiznet.io/Product/Chip/Ethernet/W5100>

### How One Modbus TCP Request Is Handled

Let's run PEAK CORE as a **Modbus TCP server (port 502)** and follow a SCADA host reading 10 input registers.

1. **SCADA opens a connection to port 502.** The **W5100** receives the SYN and returns the SYN-ACK. The MCU only sees the socket status register change to `ESTABLISHED`

2. **The request frame arrives** (7-byte MBAP + function code 0x04 + start address + quantity = 12 bytes). The W5100 **strips the IP and TCP headers, verifies checksums and sends the ACK**. Only the 12-byte payload lands in the RX buffer

3. **The ATmega2560 reads those 12 bytes over SPI.** It parses the function code, reads A0–A9 with `analogRead()` and builds the response PDU. **That is all the MCU does**

4. **The MCU writes the response into the TX buffer and issues a "send" command.** The **W5100** builds the TCP segment, sequence numbers and checksums, and **retransmits if the peer does not ACK**

5. **When SCADA closes the connection**, the library issues one disconnect command and the **W5100** handles the FIN exchange. The socket returns to a reusable state

**Think of the W5100 as the security office at a factory gate.** It checks visitors in (handshake), verifies badges (checksums), signs for deliveries (ACKs) and resends what didn't arrive (retransmission). The plant manager (the ATmega2560) only gets **a single note: "please send me the values of 10 registers."** The manager writes the answer and sends it back down.

### Without This Chip

If you paired the 8-bit AVR with a controller that only has MAC+PHY, the TCP state machine, retransmission timers and packet buffers would all have to run **inside the MCU's 8 KB of SRAM**. That memory would then be shared with the Modbus register map, the RS-485 buffers and the user's ladder logic [Inferred]. The W5100 keeps its own **16 KB of packet buffer on-chip**, so **the MCU's SRAM stays almost entirely free for application logic.**

### Budgeting the Four Sockets

In the standard `Ethernet` library, `EthernetServer` **hands its listening socket to a new client and then opens a fresh listening socket** (`available()` in `EthernetServer.cpp`). So **serving one concurrent client takes two sockets**.

| Purpose | Sockets | Notes |
| --- | --- | --- |
| Modbus TCP server, one connection | 1 | SCADA link |
| Modbus TCP server, waiting for the next client | 1 | The library reopens it automatically |
| NTP or HTTP client | 1 | Open briefly for time sync or cloud upload, then close |
| Spare | 1 | A second HMI or diagnostics |

Go past this budget and **new connections are refused or must wait.** If several upstream systems need data, **consolidate polling into one** or design so that no connection is held open for long.

## Similar Projects on WIZnet Makers

- **Connect a Controllino MAXI to Ubidots over HTTP**: Same hardware (MAXI) and the same standard `Ethernet.h` library. It uploads the A0 value to the cloud and switches relay R0 from a dashboard. As **the simplest form, one socket running an HTTP client**, it shows how the "NTP or HTTP client" row in the budget table works in practice
  → Project link: <https://maker.wiznet.io/teddy/projects/connect-a-controllino-maxi-to-ubidots-over-http/>

- **PoolMaster pool water regulation system**: An open-source project that measures pH and ORP and controls chemical pumps. It supports both a **CONTROLLINO MAXI** and an **Arduino Mega 2560 + Ethernet shield + relay shield**. The same ATmega2560 code running on a DIY board and a commercial PLC backs up PEAK CORE's "your Arduino code as-is" claim
  → Project link: <https://maker.wiznet.io/WIZnet/projects/connected-pool-water-regulation-system-poolmaster/>

- **M-Duino 42+ PLCs controlling 12 Arctic tanks**: **Four M-Duino 42+ units** control 12 climate-experiment tanks in Svalbard, Norway. They come from **the same Industrial Shields portfolio** and use the same **ATmega2560**, but with a **W5500** for Ethernet. This lets you compare how socket count changes with the chip at the same MCU class
  → Project link: <https://maker.wiznet.io/mason/projects/12-arctic-tanks-four-water-conditions-m-duino-42-plcs-keep-each-on-target/>

All three cases **attach WIZnet hardware TCP/IP to an 8-bit ATmega2560 over SPI**. The applications differ (cloud HTTP, water control, research tanks), but the network layer is solved the same way.

| Item | PEAK CORE | MAXI → Ubidots | PoolMaster | M-Duino 42+ tanks |
| --- | --- | --- | --- | --- |
| Form | Commercial PLC (no headers) | Commercial PLC | DIY or commercial PLC | Commercial PLC |
| MCU | ATmega2560 | ATmega2560 | ATmega2560 | ATmega2560 |
| Ethernet chip | **W5100** | W5100 (same MAXI) | W5100 on MAXI; depends on the shield on Mega | **W5500** |
| Hardware sockets | 4 | 4 | 4 on MAXI | 8 |
| Upper protocol | Modbus TCP, HTTP, etc. (user's choice) | HTTP | MQTT (author's README) | WebSocket |
| Field bus | RS-485 | — | — | RS-485 |

The common pattern across these cases is "the 8-bit MCU runs the control logic, and a dedicated chip runs TCP/IP." PEAK CORE packages that structure in a **header-free OEM form**.

## Use Cases

- **Embedded controller for OEM machines**: Packaging machines, dryers and washers that fit within 10 relays and 12 DI. Machine status goes out over Ethernet to an MES or HMI. Without headers, **you save height inside the machine's control cabinet**

- **Continued production of CONTROLLINO MAXI designs**: Machines already built on MAXI can keep sourcing the same hardware under the new part number **without code changes**. Only the part number and name in the BOM change

- **Modbus RTU meters → Modbus TCP**: A **small gateway-plus-controller** that polls several energy meters or temperature controllers over RS-485 and re-exposes their values as Modbus TCP registers on Ethernet

- **OpenPLC training and small sites**: The OpenPLC Editor source has branches for CONTROLLINO MAXI and MEGA, so uploading IEC 61131-3 ladder logic and monitoring it over Modbus TCP appears feasible [Inferred]

## Limitations and Future Improvements

PEAK CORE **carries an existing 8-bit PLC design forward under a new name**. That continuity is its strength, and its limits come from the same generation.

**Current limitations**

- **Four sockets**: As the budget table shows, one server connection uses two. Running a web config page, Modbus TCP and MQTT at once is tight

- **W5100 SPI efficiency**: A comment in the standard library notes that the W5100 uses **a 4-byte frame for every byte**. It is likely a disadvantage for streaming large data, as opposed to periodic register exchange [Inferred]

- **No TLS**: The CONTROLLINO library README states that **the hardware cannot do SSL/TLS encryption, so HTTPS is not possible**. If you need a direct cloud link, put **a gateway that handles TLS** in front

- **Shared SPI and CS handling**: CONTROLLINO README FAQ 7 warns that floating CS lines for the RTC (PJ2) and the WIZnet chip (PJ3) can cause **MISO contention**. It recommends calling `Controllino_RTC_init()` before using SPI. CORE has no headers, so external SPI devices are rare, but the rule still applies if your firmware drives SPI directly

- **Inconsistent published figures**: The product page and the datasheet disagree

| Item | Product page | Datasheet (Rev.1.0) |
| --- | --- | --- |
| Relay contacts | 10 A / 240 V AC | **6 A / 250 V AC, 30 V DC** |
| Operating temperature | −10 to +55 °C | **0 to 55 °C** |
| Ethernet access | "accessible via terminal blocks" | **RJ45, 10/100 Mbps** |

The CONTROLLINO library README also rates the MAXI relays at **230 V / 6 A**. **Designing to the datasheet values (6 A, 0 °C) is the safer choice.Future improvements**

- **Move to the W5500 generation**: The M-Duino from the same Industrial Shields portfolio and the sibling NEXTuino BASE already use the **W5500 (8 sockets)** (socket count per WIZnet's official documentation). The standard `Ethernet` library **auto-detects** W5100, W5200 and W5500 (`isW5100()`/`isW5500()` in `w5100.cpp`), so a later revision could switch chips with **little or no change to user code** [Inferred]
  → W5500 documentation: <https://docs.wiznet.io/Product/Chip/Ethernet/W5500>

- **Clean up published material**: Aligning the web and datasheet figures left over from the rebrand, and naming the Ethernet chip in the datasheet, would make OEM design reviews easier

## FAQ

**Q1. Can I run CONTROLLINO MAXI code on PEAK CORE as-is?** The PCN states "No change" for both hardware and firmware. Pin macros (such as `CONTROLLINO_R0`) and `Ethernet` code should work unchanged. However, CORE **has no pin headers**, so code that uses header pins (such as X1) does not apply.

**Q2. What do I install for development?** Install the **CONTROLLINO board package** from the Arduino IDE Boards Manager and use `#include <Controllino.h>`. For Ethernet, use the standard `Ethernet.h`.

**Q3. What if four sockets are not enough?** Consolidate server connections to a single upstream system, and **open client tasks such as HTTP and NTP briefly, then close them.** If that still falls short, it is time to look at a sibling product with a W5500 (8 sockets).

**Q4. How does it differ from the NEXTuino BASE with a W5500?** BASE is an **RP2040 (264 KB SRAM) + W5500**. PEAK CORE is an **ATmega2560 (8 KB SRAM) + W5100**. Both hand TCP/IP to the chip. They differ in socket count (8 vs. 4) and MCU headroom.

**Q5. Which relay rating should I trust?** Design to **the 6 A / 250 V AC in datasheet Rev.1.0**. Older CONTROLLINO documents also say 6 A. The common relay terminal is rated **6 A** maximum as well.

→ Datasheet: <https://www.nextuino.com/assets/datasheets/NEXTuino_PEAK_CORE_Datasheet.pdf>

---

---

## 요약

**NEXTuino PEAK CORE**는 **ATmega2560** 기반 DIN 레일 PLC입니다. 제조사 제품군 개요의 CONTROLLINO 대응표에 따르면 옛 **CONTROLLINO MAXI Pure**에 해당하고, 2026년 품번 변경 통지(PCN)는 옛 품번 **100.100.10**에서 **이름과 품번만 바뀌었을 뿐 회로·펌웨어는 그대로**라고 밝힙니다. Ethernet은 **WIZnet W5100**이 맡습니다. 이 칩이 **TCP/IP를 하드웨어로 처리(TOE)** 하기 때문에, SRAM이 **8 KB**뿐인 8비트 MCU도 Modbus TCP 서버나 HTTP 클라이언트로 동작합니다.

→ 제품 페이지: <https://www.nextuino.com/products/peak/core>

## 개요

PEAK CORE는 **OEM 장비 제작사와 패널 빌더**를 겨냥한 소형 PLC입니다. 72 × 90 × 62 mm 크기에 **디지털 입력 12개**(그중 10개는 아날로그 겸용), **트랜지스터 출력 12개**, **릴레이 출력 10개**, **RS-485**, **Ethernet**을 담았습니다. 프로그래밍은 Arduino IDE에서 `setup()`/`loop()` 그대로 합니다.

이름의 **CORE**는 **Arduino 핀헤더를 뺀 변형**이라는 뜻입니다. 제조사는 "MCU와 I/O 매핑이 동일해 PEAK 펌웨어가 그대로 돈다"고 밝히고, 헤더를 빼서 높이와 BOM을 줄였다고 설명합니다. 실드로 확장할 일이 없는 양산 장비에 맞춘 구성입니다.

같은 하드웨어는 maker.wiznet.io에서 이미 **CONTROLLINO MAXI**라는 이름으로 여러 차례 소개됐습니다. 이 글은 그 글들이 다루지 않은 **이름이 바뀐 경위**, **W5100이 8 KB MCU에서 맡는 일**, **소켓 4개를 나눠 쓰는 법**에 집중합니다.

→ 기존 소개 글: <https://maker.wiznet.io/irina/resellers/controllino-maxi/>
→ 형제 변형 글: <https://maker.wiznet.io/bruno/resellers/controllino-maxi-power-automation-1/>

## 이름이 바뀐 이유 — CONTROLLINO에서 NEXTuino까지

### 계보

| 시점 | 일 | 근거 |
| --- | --- | --- |
| 출시 시점 확인 불가 | 오스트리아 인스브루크의 **Conelcom GmbH**가 Arduino 호환 PLC **CONTROLLINO**(MINI·MAXI·MEGA)를 내놓습니다 | CONTROLLINO 매뉴얼의 제조사 표기 |
| **2024-10-31** | 스페인 바르셀로나의 **Industrial Shields**(Boot & Work Corp)가 CONTROLLINO 브랜드의 **독점 생산·마케팅**을 넘겨받습니다. 창업자 Marco Riedesser는 설계에 계속 참여합니다 | 업계 보도(automation.com), 회사명은 PCN 머리글 |
| **2026-05-01** 적용 | Industrial Shields가 **PCN-IS-2026-001**(2026-07-08 발행)로 CONTROLLINO 호환 품번을 **NEXTuino 12자리 품번**으로 바꿉니다 | PCN 원문 |

→ PCN 원문(RS 문서 서버): <https://docs.rs-online.com/1718/A700000015864598.pdf>
→ 제휴 보도: <https://www.automation.com/article/agreement-industrial-shields-controllino>

### PCN이 말하는 것

PCN의 영향 평가표는 **Form·Fit·Function·하드웨어 리비전·소프트웨어/펌웨어·가격·리드타임이 모두 "변경 없음"** 이고, "품번만 바뀐다"고 명시합니다. PEAK 계열과 CREST CORE의 대응은 다음과 같습니다.

| 옛 품번 | NEXTuino 이름 | 새 품번 |
| --- | --- | --- |
| 100.100.00 | NEXTuino **PEAK** | 042003000100 |
| **100.100.10** | NEXTuino **PEAK CORE** | **042003000200** |
| 100.101.00 | NEXTuino PEAK FLEX | 042003000300 |
| 100.101.10 | NEXTuino PEAK FLEX CORE | 042003000400 |
| 100.200.10 | NEXTuino CREST CORE | 042004000200 |

PEAK CORE 데이터시트 머리말의 품번도 **042003000200 Rev.1.0**으로 PCN의 새 품번과 같습니다. 제조사의 제품군 개요(Family Overview) 데이터시트는 **PEAK CORE = CONTROLLINO MAXI Pure**로 대응시킵니다.

→ 제품군 개요: <https://www.nextuino.com/assets/datasheets/NEXTuino_Family_Overview_Datasheet.pdf>

**독자에게 의미하는 것**은 하나입니다. **CONTROLLINO MAXI용으로 쓴 코드, 핀 매크로, 포럼 답변이 PEAK CORE에서도 그대로 통합니다.** 판매처에 따라 아직 옛 이름이 남아 있으니, 구매할 때는 **품번**으로 대조하는 편이 안전합니다.

### 규격 측면

데이터시트는 적용 규격으로 **EN 61010-1 / EN 61010-2-201 / EN 61131-2**를 적었습니다. EN 61131-2는 PLC 장비의 기능·EMC 요구사항과 시험을 다루는 규격이고, 61010-2-201은 제어 장비의 전기 안전 규격입니다. 인증서 번호는 공개 자료에서 확인되지 않습니다.

## 아키텍처

핀 번호는 CONTROLLINO 라이브러리의 `Controllino.h` MAXI 정의에서 확인했습니다.

- **Ethernet**: `CONTROLLINO_ETHERNET_CHIP_SELECT 70`, `CONTROLLINO_ETHERNET_INTERRUPT 71`

- **RTC**: `CONTROLLINO_RTC_CHIP_SELECT 72`, `CONTROLLINO_RTC_INTERRUPT 73`

- **RS-485**: `CONTROLLINO_RS485_TX 14`, `CONTROLLINO_RS485_RX 15`, `CONTROLLINO_RS485_DE 75`, `CONTROLLINO_RS485_nRE 76`

→ 라이브러리: <https://github.com/CONTROLLINO-PLC/CONTROLLINO_Library>

**W5100과 RTC가 SPI 버스 하나를 함께 씁니다.** 칩 선택 핀으로 둘을 나누는 구조라 펌웨어가 CS 핀을 제대로 다뤄야 합니다. 이 내용은 「한계 및 개선 방향」에서 다룹니다.

## 기술 배경

### Modbus RTU와 Modbus TCP — 같은 명령, 다른 운반 방식

- **개념**: Modbus는 "어느 레지스터를 읽고 쓸지"를 정한 **응용 계층 프로토콜**입니다. 명령 부분(PDU: 기능 코드 + 데이터)은 RTU와 TCP가 같고, **운반 방식만 다릅니다**

- **RTU**: 시리얼(RS-485) 위에서 **슬레이브 주소 + PDU + CRC-16**으로 프레임을 만들고, 문자 사이의 침묵 시간으로 프레임 경계를 판단합니다

- **TCP**: **포트 502**의 TCP 연결 위에서 **7바이트 MBAP 헤더 + PDU**를 보냅니다. 오류 검출과 재전송은 TCP가 맡으므로 CRC를 붙이지 않습니다

- **이 제품에서의 역할**: PEAK CORE는 **RS-485(RTU)와 Ethernet(TCP)을 함께 갖춘** 소형 PLC입니다. 현장 계측기는 RS-485로 묶고, 상위 SCADA나 HMI에는 Ethernet으로 같은 레지스터를 내보내는 **양쪽 다리** 역할이 가능합니다. OpenPLC 에디터의 펌웨어 소스에는 `CONTROLLINO_MAXI`·`CONTROLLINO_MEGA`일 때 `Controllino.h`를 불러오는 분기가 있습니다

→ Modbus 규격: <https://www.modbus.org/modbus-specifications>
→ OpenPLC 에디터 소스: <https://github.com/Autonomy-Logic/openplc-editor>

### EN 61131-2와 EN 61010-2-201 — PLC 장비 규격이 데이터시트에 남기는 흔적

- **개념**: IEC/EN 61131-2는 PLC 장비의 **기능 요구사항(전원·입출력 특성 등)과 EMC 요구사항, 그 검증 시험**을 정한 규격입니다. 2017년판부터 **안전 요구사항은 IEC 61010-2-201**로 넘겼습니다

- **동작 원리의 핵심**: 일반 마이크로컨트롤러 보드가 "3.3 V 로직"을 말한다면, PLC 규격은 **12/24 V 필드 전압에서 어디까지가 0이고 어디부터 1인지**, 정전기와 서지를 얼마나 견디는지를 묻습니다

- **이 제품에서의 역할**: 데이터시트의 숫자들은 이 두 규격이 묻는 항목에 대한 답입니다
  - 24 V 범위 입력: **0~~7.2 V는 Low, 18~~26.4 V는 High**, 입력 전류 **3 mA 미만**
  - 정전기 방전: **접촉 ±4 kV / 기중 ±8 kV**
  - 충격: **15 g, 11 ms 반정현파**, 3축 모두
  - 진동: **5~9 Hz는 1.75 mm 진폭**, **9~150 Hz는 0.5 g**(정현파 기준)
  - 오염도 **PD2**, 고도 **2000 m** 이하

이 숫자들이 **"Arduino 보드를 케이스에 넣은 것"과 PLC의 차이**입니다.

## 기술 특징

- **헤더를 뺀 CORE**: PEAK와 I/O 매핑이 같고 핀헤더만 없습니다. 실드를 꽂을 일이 없는 장비 안에서는 **높이와 부품 수가 줄어듭니다**

- **12 V / 24 V 공용 + LED로 판별**: 전원 LED 두 개가 입력 전압 범위(10.2~~15.0 V / 20.4~~30.0 V)에 따라 **초록·주황으로 바뀝니다**. 현장에서 전원 범위를 바로 확인할 수 있습니다

- **릴레이는 절연, DI/DO는 비절연**: 릴레이는 **코일-접점 3000 V AC 1분** 절연입니다. 디지털 입력과 트랜지스터 출력은 **"no galvanic insulation"** 으로 명시돼 있어 같은 접지 기준 안에서 써야 합니다

- **PWM과 릴레이**: 트랜지스터 출력은 **듀티 5~95 % PWM**을 지원합니다. 릴레이를 PWM으로 구동할 때는 **듀티 30 % 초과**에서 켜진다고 적혀 있습니다

- **RTC 내장**: SPI에 **RV-2123** RTC가 있어 Ethernet 없이도 시각 기반 스케줄을 돌릴 수 있습니다

- **RS-485는 종단 저항이 없습니다**: 버스 끝단이면 120 Ω을 외부에 달아야 합니다(데이터시트 "no termination inside")

## W5100이 맡는 일 — 8 KB SRAM에서 TCP를 덜어내기

### TOE 판정: 사용함

PEAK CORE의 Ethernet은 **W5100의 하드웨어 TCP/IP(TOE)** 로 동작합니다. 근거는 다음과 같습니다.

- 제품 페이지의 통신 항목에 **"Ethernet (W5100)"** 이 명시돼 있습니다

- CONTROLLINO BSP 3.0.0부터 **표준 Arduino `Ethernet` 라이브러리**를 씁니다(라이브러리 README FAQ 9). 이 라이브러리는 lwIP 같은 소프트웨어 스택이 없고, **WIZnet 칩의 하드웨어 소켓을 레지스터로 직접 다룹니다**

- 라이브러리 `socket.cpp`에는 `if (chip == 51) maxindex = 4;` 가 있습니다. W5100(칩 ID 51)이면 **하드웨어 소켓 4개**까지만 쓴다는 뜻입니다

**W5100 주요 사양**(WIZnet 공식 문서 기준)

| 항목 | 값 |
| --- | --- |
| 하드웨어 소켓 | **4개** 동시 |
| 내부 버퍼 | **16 KB** (송신 8 KB + 수신 8 KB, 각각 소켓별로 배분) |
| 하드웨어 처리 프로토콜 | TCP, UDP, ICMP, IGMPv1/v2, IPv4, ARP, PPPoE |
| PHY | 10BASE-T / 100BASE-TX 내장, 자동 협상 |
| 호스트 인터페이스 | SPI 또는 병렬 버스 |

→ W5100 문서: <https://docs.wiznet.io/Product/Chip/Ethernet/W5100>

### Modbus TCP 요청 하나가 처리되는 과정

PEAK CORE를 **Modbus TCP 서버(포트 502)** 로 두고, SCADA가 입력 레지스터 10개를 읽는 상황을 따라가 보겠습니다.

1. **SCADA가 포트 502로 연결을 요청합니다.** SYN을 받고 SYN-ACK을 돌려 연결을 맺는 일은 **W5100**이 합니다. MCU는 소켓 상태 레지스터가 `ESTABLISHED`로 바뀐 것만 확인합니다

2. **요청 프레임이 도착합니다**(MBAP 7바이트 + 기능 코드 0x04 + 시작 주소 + 개수 = 12바이트). W5100이 **IP·TCP 헤더를 벗기고 체크섬을 검사하고 ACK을 보낸 뒤**, 12바이트 페이로드만 수신 버퍼에 남깁니다

3. **ATmega2560은 SPI로 12바이트를 읽습니다.** 기능 코드를 해석하고 `analogRead()`로 A0~A9를 읽어 응답 PDU를 만듭니다. **MCU가 하는 일은 여기까지입니다**

4. **MCU가 응답 바이트를 송신 버퍼에 쓰고 "보내라" 명령을 줍니다.** TCP 세그먼트 구성, 시퀀스 번호, 체크섬, **상대가 ACK을 안 보내면 재전송**하는 일은 **W5100**이 합니다

5. **SCADA가 연결을 닫으면** 라이브러리가 끊기 명령을 한 번 주고, FIN 교환은 **W5100**이 처리합니다. 소켓은 다시 쓸 수 있는 상태로 돌아갑니다

**비유하면 W5100은 공장 정문의 경비실입니다.** 방문객 확인(핸드셰이크), 출입증 확인(체크섬), 받은 서류의 수령증(ACK), 상대가 못 받았을 때 다시 보내는 일(재전송)은 경비실이 처리합니다. 공장장(ATmega2560)에게는 **"레지스터 10개 값을 알려 달라"는 쪽지 한 장만** 올라옵니다. 공장장은 쪽지에 답만 써서 내려보내면 됩니다.

### 이 칩이 없었다면

8비트 AVR에 MAC+PHY만 있는 컨트롤러를 붙이면, TCP 상태 기계, 재전송 타이머, 패킷 버퍼를 **MCU의 8 KB SRAM 안에서** 직접 돌려야 합니다. 그러면 Modbus 레지스터 맵, RS-485 버퍼, 사용자 래더 로직과 메모리를 나눠 써야 합니다 [추정]. W5100은 패킷 버퍼 **16 KB를 칩 안에 따로** 갖고 있어서, **MCU의 SRAM은 응용 로직에 거의 그대로 남습니다.**

### 소켓 4개 예산 짜기

표준 `Ethernet` 라이브러리의 `EthernetServer`는 클라이언트가 붙으면 **대기하던 소켓을 그 연결에 넘기고, 대기 소켓을 새로 하나 엽니다**(`EthernetServer.cpp`의 `available()`). 따라서 **서버에 동시 접속 1개를 받으려면 소켓 2개**가 필요합니다.

| 용도 | 소켓 | 비고 |
| --- | --- | --- |
| Modbus TCP 서버 — 접속 1개 | 1 | SCADA 연결 |
| Modbus TCP 서버 — 다음 접속 대기 | 1 | 라이브러리가 자동으로 다시 엶 |
| NTP 또는 HTTP 클라이언트 | 1 | 시각 동기화나 클라우드 전송은 짧게 열고 닫기 |
| 예비 | 1 | 두 번째 HMI 접속 또는 진단용 |

이 예산을 넘기면 **새 연결이 거부되거나 기존 연결을 기다려야 합니다.** 상위 시스템이 여러 대라면 **폴링하는 쪽을 하나로 모으거나**, 연결을 오래 붙잡지 않도록 설계하는 편이 안정적입니다.

## WIZnet Makers 유사 사례

- **Controllino MAXI를 HTTP로 Ubidots에 연결하기** — 같은 하드웨어(MAXI)에 같은 표준 `Ethernet.h` 라이브러리를 쓰고, A0 값을 클라우드로 올리고 릴레이 R0을 대시보드에서 켭니다. **소켓 하나로 HTTP 클라이언트를 돌리는 가장 단순한 형태**로, 위 예산표의 "NTP 또는 HTTP 클라이언트" 칸이 실제로 어떻게 쓰이는지 보여줍니다
  → 프로젝트 링크: <https://maker.wiznet.io/teddy/projects/connect-a-controllino-maxi-to-ubidots-over-http/>

- **PoolMaster 수영장 수질 조절 시스템** — pH·ORP를 재고 약품 펌프를 제어하는 오픈소스 프로젝트입니다. **CONTROLLINO MAXI**와 **Arduino Mega 2560 + Ethernet 실드 + 릴레이 실드** 두 구성을 모두 지원합니다. 같은 ATmega2560 코드가 DIY 보드와 상용 PLC 양쪽에서 돈다는 점이 PEAK CORE의 "Arduino 코드 그대로"라는 주장을 실제로 보여줍니다
  → 프로젝트 링크: <https://maker.wiznet.io/WIZnet/projects/connected-pool-water-regulation-system-poolmaster/>

- **북극 수조 12개를 제어하는 M-Duino 42+ PLC** — 노르웨이 스발바르의 기후 실험 수조 12개를 **M-Duino 42+ 4대**로 제어합니다. **같은 Industrial Shields 제품군**에 같은 **ATmega2560**이지만 Ethernet은 **W5500**입니다. 같은 MCU 급에서 칩에 따라 소켓 수가 어떻게 달라지는지 비교할 수 있습니다
  → 프로젝트 링크: <https://maker.wiznet.io/mason/projects/12-arctic-tanks-four-water-conditions-m-duino-42-plcs-keep-each-on-target/>

세 사례 모두 **8비트 ATmega2560에 WIZnet 하드웨어 TCP/IP를 SPI로 붙인 구조**입니다. 응용(클라우드 HTTP, 수질 제어, 연구용 수조)이 달라도 네트워크 계층은 같은 방식으로 풀었습니다.

| 항목 | PEAK CORE | MAXI → Ubidots | PoolMaster | M-Duino 42+ 수조 |
| --- | --- | --- | --- | --- |
| 형태 | 상용 PLC (헤더 없음) | 상용 PLC | DIY 또는 상용 PLC | 상용 PLC |
| MCU | ATmega2560 | ATmega2560 | ATmega2560 | ATmega2560 |
| Ethernet 칩 | **W5100** | W5100 (MAXI 동일) | MAXI 구성은 W5100, Mega 구성은 실드에 따라 다름 | **W5500** |
| 하드웨어 소켓 | 4 | 4 | MAXI 구성은 4 | 8 |
| 상위 프로토콜 | Modbus TCP·HTTP 등 (사용자 선택) | HTTP | MQTT (원저자 README) | WebSocket |
| 필드 버스 | RS-485 | — | — | RS-485 |

세 사례에서 공통으로 보이는 구성은 "8비트 MCU는 제어 로직만 맡고, TCP/IP는 전용 칩에 맡긴다"는 것입니다. PEAK CORE는 그 구조를 **헤더 없는 OEM 형태**로 정리한 제품입니다.

## 어디에 쓰나

- **OEM 장비의 내장 제어기**: 포장기, 건조기, 세척기처럼 릴레이 10개와 DI 12개 안에서 끝나는 장비에 넣고, 장비 상태는 Ethernet으로 상위 MES나 HMI에 내보냅니다. 헤더가 없어 **장비 안 전장함 높이를 아낄 수 있습니다**

- **CONTROLLINO MAXI 기반 설계의 계속 생산**: 이미 MAXI로 만든 장비라면 **코드 수정 없이** 같은 하드웨어를 새 품번으로 계속 조달할 수 있습니다. 바뀌는 것은 BOM의 품번과 이름뿐입니다

- **Modbus RTU 계측기 → Modbus TCP 묶음**: 전력량계나 온도 조절기 여러 대를 RS-485로 폴링하고, 그 값을 Ethernet 쪽 Modbus TCP 레지스터로 다시 내보내는 **소형 게이트웨이 겸 제어기**

- **OpenPLC 교육·소규모 현장**: OpenPLC 에디터 소스에 CONTROLLINO MAXI·MEGA용 분기가 있어, IEC 61131-3 래더로 짠 로직을 올리고 Modbus TCP로 감시하는 구성이 가능할 것으로 보입니다 [추정]

## 한계 및 개선 방향

PEAK CORE는 **기존 8비트 PLC 설계를 이름만 바꿔 이어가는 제품**입니다. 그 연속성이 장점이고, 한계도 그 세대에서 옵니다.

**현재 한계**

- **소켓 4개**: 위 예산표처럼 서버 접속 하나에 두 개가 들어갑니다. 웹 설정 페이지, Modbus TCP, MQTT를 한꺼번에 돌리기에는 빠듯합니다

- **W5100 SPI 효율**: 표준 라이브러리 주석은 W5100이 **바이트 하나마다 4바이트 프레임**을 쓴다고 적고 있습니다. 주기적인 레지스터 교환보다 큰 데이터를 연속으로 보내는 용도에서 불리할 것으로 보입니다 [추정]

- **TLS 미지원**: CONTROLLINO 라이브러리 README는 **이 하드웨어가 SSL/TLS 암호화를 할 수 없어 HTTPS를 쓸 수 없다**고 적고 있습니다. 클라우드 직결이 필요하면 **TLS를 처리하는 게이트웨이**를 앞에 두는 구성이 현실적입니다

- **SPI 공유와 CS 처리**: CONTROLLINO README FAQ 7은 RTC(PJ2)와 WIZnet 칩(PJ3)의 CS가 떠 있으면 **MISO 충돌**이 날 수 있다고 적고, SPI를 쓰기 전에 `Controllino_RTC_init()`를 부르라고 안내합니다. CORE는 헤더가 없어 외부 SPI 장치를 붙일 일이 적지만, 펌웨어에서 SPI를 직접 다룬다면 지켜야 할 규칙입니다

- **공개 자료의 수치 불일치**: 제품 페이지와 데이터시트의 값이 다릅니다

| 항목 | 제품 페이지 | 데이터시트 (Rev.1.0) |
| --- | --- | --- |
| 릴레이 접점 | 10 A / 240 V AC | **6 A / 250 V AC, 30 V DC** |
| 동작 온도 | −10 ~ +55 °C | **0 ~ 55 °C** |
| Ethernet 접속 | "단자대로 접근" | **RJ45, 10/100 Mbps** |

CONTROLLINO 라이브러리 README도 MAXI 릴레이를 **230 V / 6 A**로 적고 있습니다. **설계에는 데이터시트 값(6 A, 0 °C)을 기준으로 삼는 편이 안전합니다.개선 방향**

- **W5500 세대로 옮기기**: 같은 Industrial Shields 제품군의 M-Duino와 형제 NEXTuino BASE는 이미 **W5500(소켓 8개)** 을 씁니다(W5500 소켓 수는 WIZnet 공식 문서 기준). 표준 `Ethernet` 라이브러리가 W5100·W5200·W5500을 **자동 판별**하므로(`w5100.cpp`의 `isW5100()`/`isW5500()`), 후속 리비전에서 칩을 바꿔도 **사용자 코드 변경은 거의 없을** 것으로 보입니다 [추정]
  → W5500 문서: <https://docs.wiznet.io/Product/Chip/Ethernet/W5500>

- **공개 자료 정리**: 리브랜딩 과정에서 생긴 웹·데이터시트 수치 차이를 맞추고, 데이터시트에 Ethernet 칩명을 적으면 OEM 설계 검토가 쉬워집니다

## FAQ

**Q1. CONTROLLINO MAXI용 코드를 PEAK CORE에서 그대로 쓸 수 있나요?** PCN은 하드웨어와 펌웨어 모두 "변경 없음"이라고 밝힙니다. 핀 매크로(`CONTROLLINO_R0` 등)와 `Ethernet` 코드는 그대로 동작한다고 보는 것이 맞습니다. 다만 CORE에는 **핀헤더가 없으므로**, 헤더 핀(X1 등)을 쓰던 코드는 해당하지 않습니다.

**Q2. 개발 환경은 무엇을 설치하나요?** Arduino IDE의 보드 매니저에서 **CONTROLLINO 보드 패키지**를 설치하고, `#include <Controllino.h>`를 씁니다. Ethernet은 표준 `Ethernet.h`를 씁니다.

**Q3. 소켓 4개가 모자라면 어떻게 하나요?** 서버 연결은 상위 시스템 하나로 모으고, HTTP·NTP 같은 클라이언트 작업은 **짧게 열고 바로 닫습니다.** 그래도 부족하다면 W5500(소켓 8개)을 쓰는 형제 제품을 검토할 시점입니다.

**Q4. W5500을 쓰는 NEXTuino BASE와 무엇이 다른가요?** BASE는 **RP2040(SRAM 264 KB) + W5500**입니다. PEAK CORE는 **ATmega2560(SRAM 8 KB) + W5100**입니다. 둘 다 TCP/IP를 칩에 맡기는 구조는 같고, 소켓 수(8 대 4)와 MCU 여유가 다릅니다.

**Q5. 릴레이 정격은 어느 값을 믿어야 하나요?데이터시트 Rev.1.0의 6 A / 250 V AC**를 기준으로 설계하기를 권합니다. 옛 CONTROLLINO 문서도 6 A로 적고 있습니다. 릴레이 공통 단자 최대 전류도 **6 A**입니다.

→ 데이터시트: <https://www.nextuino.com/assets/datasheets/NEXTuino_PEAK_CORE_Datasheet.pdf>

---

Source: https://maker.wiznet.io/scott/resellers/nextuino-peak-core--compact-atmega2560-industrial-plc/